Test Code VIP Vasoactive Intestinal Polypeptide, Plasma

Test Down Notes

This test is temporarily unavailable. As an alternate, order FVIP2, 75892. For additional details, see test update.

Reporting Name

Vasoactive Intestinal Polypeptide,P

Useful For

Detecting vasoactive intestinal polypeptide-producing tumors in patients with chronic diarrheal diseases

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Specimen Type

Plasma EDTA


Ordering Guidance


This test should not be requested on patients who have recently received radioactive material.



Specimen Required


Patient Preparation: Fasting (8 hours)

Collection Container/Tube: Lavender top (EDTA)

Submission Container/Tube: Plastic vial

Specimen Volume: 1 mL

Collection Instructions: Centrifuge and aliquot plasma into a plastic vial. Freeze immediately.


Specimen Minimum Volume

0.55 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Plasma EDTA Frozen 90 days

Reference Values

<75 pg/mL

Day(s) Performed

Monday, Wednesday

Test Classification

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information

84586

LOINC Code Information

Test ID Test Order Name Order LOINC Value
VIP Vasoactive Intestinal Polypeptide,P 3125-2

 

Result ID Test Result Name Result LOINC Value
8150 Vasoactive Intestinal Polypeptide,P 3125-2

Report Available

4 to 8 days

Reject Due To

Gross hemolysis Reject
Gross lipemia Reject
Gross icterus OK

Method Name

Radioimmunoassay (RIA)

Secondary ID

8150