Test Code Lipase Lvl LIPASE – SERUM
Patient Preparation
No special patient preparations required
Collection Method
Venous collection
Minimum Volume
Adults |
1.0 mL |
Pediatric |
0.5 mL |
Container
Lt Green / Plasma Separator / Lithium Heparin
Preferred Specimen
Light Green Top (lithium heparin) plasma
Acceptable Specimen(s)
Serum:
-Gold Top SST
-Red Top
Plasma:
-Lt Green top (lithium heparin)
Reference or Target Ranges
Adults |
12 - 53 U/L |
Reportable Units
U/L
Critical Value
Not defined for this assay
Reasons for Rejection
Hemolysis Threshold: |
200 - 500 mg/dL |
Icterus Threshold: |
25 mg/dL (unconjugated) |
|
35 mg/dL (conjugated) |
Lipemia Threshold: |
1000 mg/dL |
Other: |
QNS, contaminated, improperly labeled, improper specimen type |
Specimen Stability
Ambient |
24 Hours |
Refrigerated |
7 Days |
Frozen |
1 Year |
Performance Information
Days and Time Performed |
24/7 |
Expected Turn Around Time |
Stat: 1 Hour, Routine: 4 Hours |
Stat Availability |
Yes |
Performing Bench |
CRMC Chemistry |
Methodology/Method Description |
Atellica |
Additional Information / Important Notes
After acute pancreatitis the lipase activity increases within 4-8 hours, reaches a peak after 24 hours and decreases after 8-14 days. However, there is no correlation between the lipase activity determined and the extent of damge to the pancreas.
Methodology/Method Description
Atellica CH Analyzer
CPT Codes
83690