Test Code FSH FOLLICLE STIMULATING HORMONE (FSH)

Patient Preparation

No special patient preparations required

Collection Method

Venous collection

Minimum Volume

Adults

1.0 mL

Pediatric

0.8 mL

Container

Lt Green / Plasma Separator / Lithium Heparin

Preferred Specimen

Light Green Top (lithium heparin) plasma

Acceptable Specimen(s)

Serum:
-Gold top SST
-Red Top
Plasma:
-Lt Green Top
-Lavender (LAV) top

Reference or Target Ranges

Female:

 

Follicular phase:

2.5 – 10.2 mIU/mL

Midcycle phase:

3.4 -33.4 mIU/mL

Luteal phase:

1.5 – 9.1 mIU/mL

Postmenopausal: 

23.0 – 116.3

Males:

1.4 – 18.1 mIU/mL

Reportable Units

mIU/mL

Critical Value

Not defined for this assay

Reasons for Rejection

Hemolysis Threshold:

150 mg/dL

Icterus Threshold:

20 mg/dL

Lipemia Threshold:

500 mg/dL

Other:

QNS, contaminated, improperly labeled, improper specimen type

Specimen Stability

Ambient

8 Hours separated from cells

Refrigerated         

48 Hours tightly capped

Frozen

If not assayed within 48 hours

Performance Information

Hemolysis Threshold:

150 mg/dL

Icterus Threshold:

20 mg/dL

Lipemia Threshold:

500 mg/dL

Other:

QNS, contaminated, improperly labeled, improper specimen type

Methodology/Method Description

Atellica CH Analyzer

CPT Codes

83001